CMG-3T (120 sec) weak motion broadband seismometer |
||
|
![]() |
|
Features |
|
Specifications | |
Standard velocity output band |
120 s -50 Hz' |
Mass position output band |
DC - 120 s |
Output sensitivity |
2 * 1000 V/m/s** |
Peak output | ±10 V differential |
Lowest spurious resonance | > 140 Hz (vertical) |
Linearity, vertical (USGS) | > 111 dB |
Linearity, horizontal (USGS) | > 107 dB |
Cross-axis rejection | >62dB |
Remote control |
Lock, unlock, centre |
Operating temperature | -20 to+75 °C (-55 °C optional) |
Temperature sensitivity | < 0.6 V per 10 °C |
Mass recentring range | ± 2.5 ° from horizontal |
Materials | Stainless steel case Mil-spec connector (1500 psi waterproof connector or user connector optional) |
Case diameter | 168 mm |
Case height (with handle) | 344 mm |
Case height (sensor only) |
274 mm |
Isolating power supply |
10 - 36 V DC |
Optional low power sensor | 5 V DC supply (output ±4.5 V) |
Current at 12 V DC | 75 mA |
Calibration controls | Independent signal & enable lines exposed on sensor connector |
Optional low pass corner |
50 Hz, 100 Hz or 200 Hz |